// SaherElm IT Center MQL5 XEU5 Signal Provider Library Inputs
// -----------------------------------------------------------
//
// Maintainer:
// ------------
// Hadi Khazaee Asl (hadi_khazaee_asl@yahoo.com)
//
//////////////////////////////////////////////////////
//
// Global Properties ...
#property library
#property copyright "Copyright 2023, SaherElm IT Center"
#property link "https://www.saherelm.ir"
#property version "1.00"
#property strict
//
// Include Logger ...
#include "../Libraries/x-saherelm.log.lib.mq5"
//
// Include Classes ...
#include "../Classes/x-saherelm.class.lib.mq5"
//
input group "XEU5 Provider";
//
// Commonly Used Configurations ...
input group "XEU5 Common";
//
// Provider ...
input bool xEU5EnableProvider = true; // Enable Provider
input int xEU5NumberOfItemsPerTick = 30; // Number Of items Readed In Each Tick
//
// Alerts ...
input bool xEU5EnableAlerts = true; // Enable Events Alert
input bool xEU5EnableHourlyAlerts = false; // Send Alert on each new Hour
input bool xEU5EnableDailyAlerts = false; // Send Alert on each new Day
input bool xEU5EnableWeeklyAlerts = false; // Send Alert on each new Week
input bool xEU5EnableMonthlyAlerts = false; // Send Alert on each new Month
//
// Reports ...
input bool xEU5EnableDailyReports = false; // Send Report on each new Day
input bool xEU5EnableWeeklyReports = false; // Send Report on each new Week
input bool xEU5EnableMonthlyReports = false; // Send Report on each new Month
//
// Trader and Expert Specific Configurations ...
input group "XEU5 Trader";
input int xEU5MagicNumber = 16940560; // Trader MagicNumber
input int xEU5Slippage = 10; // Trader Slippage
//
// Trades Management Configurations ...
input group "XEU5 Trade Management";
input bool xEU5AllowLongTrades = true; // Allow Long Trades
input bool xEU5AllowShortTrades = true; // Allow Short Trades
//
// Risk Management Configurations ...
input group "XEU5 Risk Management";
//
// Trade Count ...
input int xEU5MaxAllowedTrades = 10; // Max Allowed Trades at Same Time
input ENUM_X_CROSS_SIGNAL_METHOD xEU5CrossSignalsMethod = X_CROSS_SIGNAL_REGULAR; // Handle Cross Signals Method
//
// Max Allowed Trade Age ...
input int xEU5MaxAllowedTradeAge = 1500; // Detect Long Time Trades
input ENUM_X_GUARD_ACTIONS xEU5OldTradesAction = X_GUARD_PARTIAL_CLOSE_MAX_IN_DD_1; // What to do with Old Trades
//
// Trade Volume Specific Configurations ...
input double xEU5StaticVolumeFactor = 0.0002; // Static Volume baesd on Balance
input ENUM_STATIC_VOLUME_METHODS xEU5StaticVolumeMethod = X_STATIC_VOLUME_BASED_ON_BALANCE; // How to Calculate Static Volume
input double xEU5VolumeMultiplier = 0; // Volume Increase Multiplier
input double xEU5ApplyVolumeMultiplierFactor = 0; // Apply Volume Multiplier Rate based on Balance
input double xEU5MaxSupportedVolumePerTradeFactor = 0; // Max Supported Volume Per Trade Factor based on Balance
input double xEU5IncreasedMaxSupportedVolumeRate = 0; // Increase Max Supported Volume based on Balance
//
// Trade Profits ...
input double xEU5MinRewardInPips = 6; // Minimum Reward Per Trade in Pips
input double xEU5RiskFreeStepInPips = 0; // Make Trades Risk Free Steps in Pips
input double xEU5RiskFreeRate = 0; // Volume Multiplier for Risk Free Trades
//
// Guard Riskable Money and Profits ...
input double xEU5CriticalDrawDownFactor = 0.20; // Critical Allowed Drawdown Factor based on Balance
input ENUM_X_GUARD_ACTIONS xEU5CriticalGuardAction = X_GUARD_PARTIAL_CLOSE_MAX_IN_DD_1; // Specify Guard Action on Critical Drawdown
input double xEU5MaxAllowedDrawDownFactor = 0.25; // Max Allowed Drawdown Factor based on Balance
input ENUM_X_GUARD_ACTIONS xEU5MaxAllowedGuardAction = X_GUARD_PARTIAL_CLOSE_MAX_IN_DD_5; // Specify Guard Action on Max Allowed Drawdown
input int xEU5GuardStopoutFiredAfterTouches = 5; // Guard Stopout all Trades if Max Allowed Drawdown touched
//
// Account Conditions for Trading ...
input double xEU5BalanceFactorForOpenTrades = 0.5; // Minimum Balance for Open Trades
input double xEU5FreeMarginFactorForOpenTrades = 0.8; // Minimum Free Margin for Open Trades
//
// May be Used Later as Input Params ...
bool xEU5UseVirtualTPSl = false; // Use Virtual TP SL
bool xEU5EnableSignalAlerts = false; // Send Signal Alert
//
// Validate Inputs before Initialization ...
bool XEU5ValidateInputs()
{
//
bool result = false;
//
// Implement Other Verifications ...
//
// Check Trading Availability ...
bool isTradeAvailable = xEU5AllowLongTrades || xEU5AllowShortTrades;
if (!isTradeAvailable)
{
LogMessage("XEU5 => Warning: Trading disabled ...");
}
//
// Chekc Number of reading items per tick ...
result = xEU5NumberOfItemsPerTick >= 5;
if (!result)
{
//
LogMessage("XEU5 invalid Number of items Reading Per Tick ...");
//
return result;
}
//
// Check Max Allowed Trades Count ...
result = isTradeAvailable && xEU5MaxAllowedTrades >= 1;
if (!result)
{
//
LogMessage("XEU5 Number of Trades not valid ...");
//
return result;
}
//
// Check Free Margin ...
result =
isTradeAvailable &&
xEU5FreeMarginFactorForOpenTrades > 0 &&
xEU5FreeMarginFactorForOpenTrades < 1;
if (!result)
{
//
LogMessage("XEU5 Invalid Free Margin ...");
//
return result;
}
//
// Check min Balance for Open Trades ...
result =
isTradeAvailable &&
xEU5BalanceFactorForOpenTrades > 0 &&
xEU5BalanceFactorForOpenTrades < 1;
if (!result)
{
//
LogMessage("XEU5 Invalid Min Balance for Open Trades ...");
//
return result;
}
//
// Check Min Reward Per Trade ...
result = xEU5MinRewardInPips > 0;
if (!result)
{
//
LogMessage("XEU5 Invalid Min Reward Per Trade ...");
//
return result;
}
//
// Check Trades Volume ...
result = xEU5StaticVolumeFactor > 0;
if (!result)
{
//
LogMessage("XEU5 Invalid Static Volume ...");
//
return result;
}
//
// Check Volume Multiplier ...
result = xEU5VolumeMultiplier >= 0;
if (!result)
{
//
LogMessage("XEU5 Invalid Volume Multiplier ...");
//
return result;
}
//
result =
xEU5CriticalDrawDownFactor == 0 || (xEU5CriticalDrawDownFactor > 0 &&
xEU5CriticalDrawDownFactor < 1);
if (!result)
{
//
LogMessage("XEU5 Invalid Critical DrawDown Factor ...");
//
return result;
}
//
result =
xEU5MaxAllowedDrawDownFactor == 0 || (xEU5MaxAllowedDrawDownFactor > 0 &&
xEU5MaxAllowedDrawDownFactor < 1);
if (!result)
{
//
LogMessage("XEU5 Invalid Max Allowed DrawDown Factor ...");
//
return result;
}
//
// Check Guard Actions ...
//
result =
xEU5CriticalDrawDownFactor > 0 &&
xEU5CriticalDrawDownFactor < 1 &&
xEU5MaxAllowedDrawDownFactor > 0 &&
xEU5MaxAllowedDrawDownFactor < 1;
if (!result)
{
//
LogMessage("XEU5 For Critical Drawdown, you have to Specify Max Drawdown also ...");
//
return result;
}
//
result = xEU5CriticalDrawDownFactor > 0 && xEU5CriticalDrawDownFactor < xEU5MaxAllowedDrawDownFactor;
if (!result)
{
//
LogMessage("XEU5 Critical Drawdown must Smaller than Max Drawdown ...");
//
return result;
}
//
if (xEU5CriticalDrawDownFactor > 0 && xEU5CriticalGuardAction == X_GUARD_DO_NOTHING)
{
LogMessage("XEU5 IMPORTANT you Specified Critical Drawdown, but there is no any Guard Action ...");
}
//
if (xEU5MaxAllowedDrawDownFactor > 0 && xEU5MaxAllowedGuardAction == X_GUARD_DO_NOTHING)
{
LogMessage("XEU5 IMPORTANT you Specified Max Allowed Drawdown, but there is no any Guard Action ...");
}
//
result = true;
//
return result;
}